ATX620 Multi-Gas Aspirated Monitor
 
Case

Type 304 Stainless Steel (case top) and high impact composite (battery housing)

 
Dimensions

8.2" x 3.7" x 3.2"
(208 mm x 94 mm x 81 mm)

 
Weight

3.4 lbs (1.5 kg)

 
Sensors

Combustible Gases/Methane - Catalytic Diffusion
Oxygen and Toxic Gases - Electrochemical

 
Measuring Ranges

Combustible Gases/General Hydrocarbons – 50 ppm to 100% LEL
Methane – 0 to 5% of volume in 0.1% increments
Oxygen – 0 to 30% of volume in 0.1% increments
Carbon Monoxide, Hydrogen Sulfide – 0 to 999 ppm in 1 ppm increments
Chlorine, Chlorine Dioxide, Nitrogen Dioxide, Sulfur Dioxide – 0.2 to 99.9 ppm in 0.1 ppm increments

 
Sample Flow Rate
0.5 LPM (1 SCFH)
 
Power Source (Run Time)

Rechargeable Ni-Cad Battery Pack (16 hours typical)
Replaceable C Cell Alkaline Battery Pack (20 hours typical)

 
Temperature Range

-4oF to 122oF (-20oC to 50oC)

 
Humidity Range

0 to 99% RH (non-condensing)

 
Approvals

UL and CSA – Class I, Groups A, B, C, D
MSHA – Intrinsically safe for Methane/Air mixtures only
CENELEC (ATEX) and Australia – EEx ia d IIC T4

 
 
 
 

 


 

 