Case |
 |
|
Type 304 Stainless
Steel (case top) and
high impact
composite (battery
housing) |
|
|
|
Dimensions |
|
8.2" x 3.7" x 3.2"
(208 mm x 94 mm x 81
mm) |
|
|
|
Weight |
|
3.4 lbs (1.5 kg) |
|
|
|
Sensors |
|
Combustible
Gases/Methane - Catalytic
Diffusion
Oxygen and Toxic
Gases
- Electrochemical |
|
|
|
Measuring Ranges |
|
Combustible
Gases/General
Hydrocarbons –
50 ppm to 100% LEL
Methane – 0
to 5% of volume in
0.1% increments
Oxygen – 0 to
30% of volume in
0.1% increments
Carbon Monoxide,
Hydrogen Sulfide
– 0 to 999 ppm in 1
ppm increments
Chlorine,
Chlorine Dioxide,
Nitrogen Dioxide,
Sulfur Dioxide –
0.2 to 99.9 ppm in
0.1 ppm increments |
|
|
|
Sample Flow Rate |
|
0.5 LPM (1 SCFH) |
|
|
|
Power Source (Run
Time) |
|
Rechargeable Ni-Cad
Battery Pack (16
hours typical)
Replaceable C Cell
Alkaline Battery
Pack (20 hours
typical) |
|
|
|
Temperature Range |
|
-4oF to 122oF (-20oC
to 50oC) |
|
|
|
Humidity Range |
|
0 to 99% RH
(non-condensing) |
|
|
|
Approvals |
|
UL and CSA – Class
I, Groups A, B, C, D
MSHA – Intrinsically
safe for Methane/Air
mixtures only
CENELEC (ATEX) and
Australia – EEx ia d
IIC T4 |