Overview

Specifications

Ordering information

Download brochure

 

 

 

Product by Gas

 
4800 Controller Ordering information
 

4800 Controller is an analog/digital input/output system controller with remote dial out and access capabilities.
Part Number = 4800-ABCDEFGH
Base unit consists of Micro-controller with display; modem, AC and phone line surge protection and 24-hour battery back up.A maximum number of 72 channels can be used, however the maximum number of modules (input and output) can not exceed 6 in any combination

Example: 4800-12010200 = NEMA 4X enclosure with 16 analog input channels, 8 ModBus RTU input channels, 8 relay contacts

 

A = Base Unit

E = Controller to controller Support Options

B = Analog Input Options

F = Relay Options

C = Digital Input Options

G = Data Logging Options

D = ModBus RTU Support Options
 

H = SCADA connection Options

 
A - Base Unit

1 = NEMA 4X Wall mount enclosure w/display and 24 hour battery back up
2 = Sub-Panel Mount w/display and 24 hour battery back up
3 = Flush Mount w/display and 24 hour battery back up

 
B - Analog Input Options   E - Controller/Controller Support Options
0 = None  

0 = None

1 = 1 - 8 Channel Analog Module

 

1 = Controller to controller communication capable

2 = 2 - 8 Channel Analog Modules(16 channels)

   

3 = 3 - 8 Channel Analog Modules (24 channels)

  F - Relay Options

4 = 4 - 8 Channel Analog Modules (32 channels)

 

0 = None

5 = 5 - 8 Channel Analog Modules (40 channels)

 

1 = 1 - 4 Relay Contact Module (4 relays)

6 = 6 - 8 Channel Analog Modules (48 channels)

 

2 = 2 - 4 Relay Contact Modules (8 relays)

   

3 = 3 - 4 Relay Contact Modules (12 relays)

C - Digital (Dry Contact) Input Options  

4 = 4 - 4 Relay Contact Modules (16 relays)

0 = None

   

1 = 4 - Channel Digital Input Module

  G- Data Logging Options

2 = 8 - Channel Digital Input Module

 

0 = None

   

1 = Data Logging

D - ModBus RTU Input Channels Support Options    

0 = None

  H - SCADA Connection Options

1 = 8 Channels of RTU Supported

 

0 = None

2 = 16 Channels of RTU Supported

 

1 = Modbus Slave support via serial, phone or
radio modem connection

3 = 24 Channels of RTU Supported

   

4 = 32 Channels of RTU Supported

   

5 = 40 Channels of RTU Supported

   

6 = 48 Channels of RTU Supported

   

7 = 56 Channels of RTU Supported

   

8 = 64 Channels of RTU Supported

   

9 = 72 Channels of RTU Supported

   
 
 
 
 

 


 

 

home  |  about us  |  products  |  training & reference library  |  service & support   |  registration  |  contact  |  sitemap

website developed by dovesoft