Gastec Tubes and Sampling Pump
Short terms quick measuring detector tubes 
  A  
  B  
  C  
  D  
  E  
  F  
  G  
  H  
  I  
  L  
  M  
  N  
  O  
  P  
  S  
  T  
  V  
  W  
  X  
Gas sampling pump kit and accessories
 
 
 
Acrylonitrile  

NO.191

CH2FCHCN
Performance  
Measuring Range
2 to 5 ppm 5 to 120 ppm 120 to 360 ppm
Number of Pump Strokes
4 2 1
Correction Factor
0.4 1 3
Sampling Time 1 minute per pump stroke
Detecting Limit 1 ppm (n=4)
Colour Change Yellow → Red
Reaction Principle Pretreatment tube: CH2:CHCN + Cr6+ + H2SO4 → HCN
Detector tube : 2HCN + HgCl2 → 2HCl + Hg(CN)2
HCl + Base → Chloride
Coefficient of Variation 10% (for 5 to 40 ppm), 5% (for 40 to 120 ppm)
Shelf Life 3 Years
Corrections for temperature & humidity Temperature correction is necessary
Store the tubes at cool and dark place.
 
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Nitriles (C3) 10 ppm + Red
Acetone cyanohidrin 10 ppm + Red
Alcohols, Esters, Ketones     No
Aromatic hydrocarbons     No
Hydrogen chloride,
Hydrogen cyanide
    No
 
Other substance measurable with this detector tube
Substance Correction Factor No. of pump strokes Measuring Range
Propionnitrile 1.0 4 50 to 120%
Calibration gas generation Diffusion tube method
TLV-TWA TLV-STEL Explosive range
2 ppm - 3 to 17%
 
 
 
   
 